High-Rise Fire Watch
High-rise fire watch planning should define floors, routes, communication, escalation and documentation around the specific impairment and authority requirements.
Get a quote
Tell us the site, dates and coverage you need. The line is answered 24/7.
- Statewide Virginia Scheduled anywhere in the Commonwealth.
- Reported every shift Written activity reporting on each shift.
- Requests any hour Nights, weekends and holidays included.
- Named escalation Escalation contacts fixed before an officer arrives.
A high-rise fire watch has to cover many floors, stairwells and elevator lobbies while a sprinkler, standpipe, fire pump or alarm system is impaired. North Eastern Security Force provides unarmed, DCJS-licensed fire watch officers who patrol the floors you and the fire official set, log every round, and stay posted until the fire official releases the watch.
When a high-rise building needs a fire watch
In Virginia, the fire official decides when a fire watch is required. When a required fire protection system is out of service, the fire department and the fire code official must be notified immediately, and the fire official may order an approved fire watch for the affected premises. In a high-rise, the impairment behind a watch might be:
- a sprinkler or standpipe zone shut down for repair, renovation or a tenant fit-out (see sprinkler outage fire watch)
- a fire pump that is down or failed testing (see fire pump impairment)
- a fire alarm panel, detection circuit or voice evacuation system that is out of service (see fire alarm outage watch)
- planned system work where the fire official requires a watch while protection is off (see planned fire system maintenance)
- hot work, or construction on occupied floors, that the permit or fire official ties to a watch (see construction fire watch)
The fire official sets the scope, the patrol frequency and how long the watch lasts. Get those instructions in writing and share them with us before the first shift.
Why tall buildings are harder to watch
High-rise buildings carry more life safety systems than most buildings, spread over many floors. Building code provisions for high-rises call for features such as automatic sprinklers, smoke detection, a voice evacuation alarm system, two-way communication in stairways, a fire command center and Phase I elevator recall. When any of these is impaired, the watch has to account for:
- Vertical distance. How long a full round takes depends on how many floors are affected, how many stairwells there are, and whether officers can use elevators.
- Occupants. Residents, office tenants or hotel guests may be on every floor, and some may need help to evacuate.
- Access. Locked tenant suites, mechanical floors, roof access and stairwell re-entry doors all need to be worked out in advance.
- Elevators. Confirm elevator use with building engineering and the fire official before the first shift, because recall or service work can take cars out of use.
For building-specific guidance, see our office building, apartment, condominium and hotel fire watch pages.
What the officer checks and logs on each round
Fire watch personnel keep watch for fires, blocked exits and other hazards, act promptly on hazards, call 911 for any fire, and help evacuate occupants. On a high-rise, a round covers the floor banks, stairwells and elevator lobbies you assign, plus the areas the impaired system protects. Depending on the post orders, it can also include mechanical rooms, the fire command center and standpipe or valve locations. Officers record:
- the date, and when each round starts and ends
- the floors and areas checked
- conditions found, such as propped fire doors, smoke or odors, or obstructed exits
- actions taken and who was notified
- the name of the officer on watch
Our fire watch log guide explains what a usable log looks like.
Coordinating with engineering, the alarm company and the insurer
For water-based systems such as sprinklers, standpipes and fire pumps, NFPA 25 lays out impairment steps for owners, including naming an impairment coordinator, tagging the impaired system, and notifying the fire department, the alarm company and the insurance carrier. Fire alarm systems fall under NFPA 72. The fire watch is one part of that plan, so the officer needs:
- the name and phone number of the impairment coordinator or chief engineer
- the alarm company’s contact details and which zones are in test or disabled
- any extra conditions your insurer has set for the impairment
- the contractor’s work schedule, especially for hot work under NFPA 51B or construction work under NFPA 241
The watch should not end just because a scheduled time has passed. The responsible contact should confirm the system is restored, and the fire official should release the watch.
What to have ready before the first shift
- The site address, the entrance officers should use, and an on-site or on-call contact.
- The fire official’s instructions, including scope, patrol frequency and any required log format.
- A list of the impaired systems and the floors or zones they protect.
- Floor plans or riser diagrams showing stairwells, standpipes, valves and the fire command center.
- Keys, access cards or escorts for locked areas, mechanical floors and stair re-entry.
- Confirmation of elevator use and how officers communicate from stairwells.
- Your evacuation plan and any occupants known to need help evacuating.
- An escalation list covering engineering, management, the alarm company and the impairment coordinator.
Our guides on how many fire watch officers you need and writing a fire watch scope of work can help you plan staffing for a tall building.
How NESF staffs a high-rise fire watch
North Eastern Security Force is licensed by Virginia DCJS under license #11-6371. All of our officers are unarmed and in uniform. For a high-rise watch, we:
- staff the watch to the fire official’s instructions
- write post orders listing the floors, routes, contacts and escalation steps
- submit a written shift report and log for every shift
- hand over logs at shift change so the next officer knows current conditions
- provide a certificate of insurance on request
We provide officers only. We do not install or repair cameras, alarm systems or fire protection equipment. Your fire protection contractor restores the system, and our officers keep watch until it is back in service. The Virginia fire watch guide and the main fire watch services page have more background.
Request high-rise fire watch coverage
Call 703-869-6213 (answered 24/7), email info@nesf.us or use the contact form. Tell us the address, the impaired system, the affected floors and the fire official’s instructions. When coverage can start depends on the building’s location and officer availability. For an outage that has just happened, see emergency fire watch.
Related services: Office building security
High-rise fire watch questions
Who decides how often the officer patrols the floors?
The fire official decides. Requirements vary by jurisdiction and building, so we staff the watch to the fire official’s written instructions and the post orders we agree with you.
Can fire watch officers use the elevators during rounds?
Only if building engineering and the fire official confirm it before the first shift. If elevators are recalled or out of service, plan for officers to use the stairs and staff the watch for that.
Will your officers fix or reset the fire alarm or sprinkler system?
No. NESF provides officers only. Your fire protection or alarm contractor restores the system, and our officers watch, log and report until the fire official releases the watch.
Can you provide proof of insurance and licensing for building management?
Yes. NESF is licensed by Virginia DCJS under license #11-6371 and fully insured. We can provide a certificate of insurance on request.
From a phone call to an officer on post.
- Tell us the site Where the site is, when it needs cover, and what matters on it.
- Post orders and rate Post orders, officer count and rate, agreed in writing first.
- Officers on post Officers work the orders, log the shift, escalate to your contact.
Coverage is scheduled around the site, the hours and officer availability.