A useful fire watch log documents the required rounds or observations, time, assigned personnel and any notable conditions or escalation required by the site procedure.
Quick answer
What information goes in a fire watch log?
A fire watch log should record each round's actual start and finish times, the officer's name and signature, and the specific areas checked. It should also note conditions observed, actions taken, every notification with time and person contacted, and shift-change signatures. In Virginia, confirm any added requirements with your local fire official under the Statewide Fire Prevention Code.
- Unarmed officers Uniformed officers, no firearms on any assignment.
- Statewide Virginia Scheduled anywhere in the Commonwealth.
- Reported every shift Written activity reporting on each shift.
- Requests any hour Nights, weekends and holidays included.
A fire watch log is the only proof that rounds were actually made while a fire protection system was impaired or hot work was underway. When a fire marshal, insurer or owner reviews it, they should be able to see who checked which areas, when, what they found, and who they told.
Who sets the log requirements in Virginia
In Virginia, fire watch falls under the Virginia Statewide Fire Prevention Code (opens in a new tab) (13VAC5-52), which incorporates the International Fire Code by reference with Virginia amendments. The local fire official, also called the authority having jurisdiction (AHJ), decides when fire watch is needed, how often rounds must be made, and what documentation they expect. Some jurisdictions publish their own guidance. Fairfax County’s fire watch personnel page (opens in a new tab), for example, lists minimum log fields (date, tour start, tour end, areas checked, findings and actions, and name) and includes a sample log. Before the first round, ask the fire official three things: the round frequency, which areas must be covered, and whether the log must stay on site for inspection.
Other standards can also shape what goes in the record. NFPA 25 (opens in a new tab) covers impairments to sprinklers and other water-based systems, including impairment tags and notifications. NFPA 72 (opens in a new tab) covers fire alarm systems, NFPA 51B (opens in a new tab) covers hot work, and NFPA 241 (opens in a new tab) covers construction, alteration and demolition sites. Your insurer may add its own impairment-notice requirements as well.
Header information to fill in before the first round
A reviewer should be able to understand the log without asking anyone. Put these details on the cover sheet or at the top of every page:
- Property name and address, with building and floor designations
- The impaired system and zones, such as the sprinkler riser serving floors three through six, or the fire alarm panel
- The impairment tag number, work order or permit reference
- The repair or service contractor and a contact number
- The round frequency and coverage areas set by the fire official, written exactly as instructed
- Contacts for the fire official, property or project representative, alarm company and on-call manager
- The date and time fire watch began
What every round entry should record
| Field | What a good entry looks like |
|---|---|
| Date and times | The actual clock time the round started and finished, not a rounded or scheduled time |
| Officer | Printed name and signature or initials |
| Areas checked | Named locations, such as “Building B floors 1-4, roof, main mechanical room,” not just “rounds” |
| Conditions observed | Specifics: smoke odor, heat, standing water, a propped fire door, blocked exit, debris near ignition sources |
| Hot work checks | Locations where hot work happened, and whether the monitoring required by the hot work permit was still underway |
| Action taken | What the officer did: closed the door, cleared the exit, called 911 |
| Notifications | Time, name and number of every person contacted |
Recording conditions, actions and notifications
The most useful part of a log is what happens when something is wrong. If an officer finds a problem, the entry should show what was found and exactly where, what the officer did, and who was told. For example: “Smoke odor, 3rd floor east corridor near unit 312. Called 911. Notified site superintendent by phone. Fire department arrived; source identified as overheated equipment.” Each step gets its own time.
The fire code requires fire watch personnel to have an approved means of notifying the fire department, and it prohibits anyone from directing a delay in reporting a fire. The log should never show a call to a manager before a 911 call for an actual fire or smoke condition.
Shift changes and log custody
- The outgoing officer finishes the final round and records it before handing over.
- Both officers review open conditions, such as a blocked exit waiting on maintenance or hot work areas still being monitored.
- Both officers sign and time the handover.
- The log stays at the agreed location on site. It does not leave with the officer.
- When fire watch ends, record the time, the person who authorized ending it, and the confirmation that the system was restored. Then give the completed log to the property or project representative.
NFPA 25 makes the owner’s impairment coordinator responsible for verifying that restoration procedures, including the required notifications, are completed once the system is back in service. A log that records when fire watch ended and who authorized it helps support that step.
Common log mistakes that weaken the record
- “All clear” with no locations. These entries cannot show what was actually inspected.
- Evenly rounded times. Rows of times that look identical or perfectly spaced suggest the log was filled in afterward.
- Missing notifications. The log shows a condition but not that anyone was told about it.
- Gaps at shift change. No signatures, or a missed round during the handover.
- No header. Pages that do not identify the system, impairment or property.
Paper or electronic logs
Either format can work if the fields are complete and the fire official accepts it. A bound paper log kept on site is always available to an inspector who shows up unannounced. An electronic system with checkpoint scanning records time and location data that is harder to dispute. If you use an electronic system, confirm with the fire official whether they also expect a paper copy or printout on site. You should also confirm how long the owner, insurer or general contractor wants the records kept.
How NESF handles fire watch logs
NESF provides unarmed, uniformed officers licensed under Virginia DCJS #11-6371. Every fire watch assignment runs on written post orders, and staffing and rounds follow the fire official’s instructions. Officers keep written shift reports and hand logs over at shift change. A certificate of insurance is available on request. The same reporting applies to fire suppression system impairments, planned fire-system maintenance, construction site security and access control posts.
Related guides: fire watch scope of work, security post orders explained, what to do when a fire alarm system is down and sprinkler system outage planning.
Request fire watch coverage
Have the site address, the impaired system, the fire official’s instructions and your on-site contact ready. Call 703-869-6213 any time, day or night, or send the details through the contact page. For an active fire, call 911 first.
Fire watch log questions
Who should keep the fire watch log when the assignment ends?
The completed log should go to the property owner or project representative who arranged the fire watch. They are responsible for the impairment record, and the fire official or insurer may ask to see it. Ask your insurer and fire official whether they expect the records to be kept for a specific period.
Does the fire official have to approve our log format?
Requirements vary by jurisdiction. Some fire officials publish a sample log or minimum fields, and others will accept any complete record. If the fire official issues a fire watch order or published guidance, use their format or make sure yours includes every field they list.
Can a security officer’s daily activity report be used as the fire watch log?
Only if it records each fire watch round separately, with actual times, named areas, conditions, actions and notifications. Fire watch is a dedicated duty, so it is usually clearer to keep a separate fire watch log than to merge the rounds into a general patrol report. Ask the fire official if you are unsure what they will accept.
What should the log show if a round is missed or delayed?
Write down the actual time the round was made and the reason for the delay, and notify the site contact. Never fill in the scheduled time instead. A reconstructed entry hurts the log’s credibility more than an honest note about a delay.
What happens after you call.
- Tell us the site The site, the hours, the gates, and what needs eyes on it.
- Post orders and rate Written post orders and a confirmed rate before anyone starts.
- Officers on post Officers work the orders, log the shift, escalate to your contact.
Coverage is scheduled around the site, the hours and officer availability.
Coverage request
Request security coverage
Tell us the site, the hours you need covered and when it starts. If the coverage is needed today, calling 703-869-6213 is faster than this form.