Fire Watch Scope of Work
Last updated · How we write and check our guides
Free template: a printable fire watch log with round, shift handover and sign-off sections.
A fire-watch scope should document the impairment, affected area, authorized procedures, communication, logging and the condition for ending coverage.
Quick answer
What should a fire watch scope of work include?
A fire watch scope of work should document the fire official's instruction, the impaired system and affected areas, the patrol route and checkpoints, staffing per shift, logging and escalation contacts, equipment and access, and start and end conditions. In Virginia, the local fire official sets the requirements, and coverage should end only on documented system restoration and release.
- Statewide Virginia Scheduled anywhere in the Commonwealth.
- Reported every shift Written activity reporting on each shift.
- Requests any hour Nights, weekends and holidays included.
- Named escalation Escalation contacts fixed before an officer arrives.
A fire watch scope of work turns the fire official’s instruction into something an officer can carry out on every shift. It names the impaired system, the areas to cover, the route, the people to call and the conditions that end coverage. This guide explains what to write in each part so the watch holds up to inspection.
Start the scope with the fire official’s instruction
In Virginia, fire watch requirements come from the local fire official, not the security vendor. The Virginia Statewide Fire Prevention Code (13VAC5-52-210 (opens in a new tab), Section 901.7.7) authorizes the fire code official to require safeguards in a building or fire area when required fire protection is out of service. The Virginia Maintenance Code (13VAC5-63-545 (opens in a new tab), Section 704.3) requires the fire department and the fire code official to be notified immediately when a required fire protection system is taken out of service. The scope should quote or attach whatever the fire official actually required. Do not paraphrase it from memory.
Before the first shift, work through these steps:
- Notify the fire department and fire code official of the impairment, and record who you spoke to and when.
- Get the fire official’s fire watch instruction, preferably in writing. It should cover round frequency, staffing and any special conditions.
- Confirm the impairment details with your fire protection contractor or the person managing the impairment. NFPA 25 (opens in a new tab) covers impairments to water-based fire protection systems, and NFPA 72 (opens in a new tab) covers fire alarm and signaling systems.
- Write the scope using the elements below and send it to the security provider.
- Walk the route with the provider’s supervisor before coverage starts.
What each scope element should say
| Element | What to write | Who supplies it |
|---|---|---|
| Authority | The fire official’s name, the jurisdiction, the date of the instruction and any conditions it sets | Owner or property manager |
| Impaired system | Which system is impaired (sprinkler, standpipe, fire pump, alarm, suppression) and which zones or floors are affected | Fire protection contractor |
| Coverage area | Buildings, floors, rooms and exterior areas included, marked on a floor plan | Owner or GC |
| Rounds | Round frequency exactly as the fire official set it | Fire official |
| Staffing | Number of officers per shift and the shift times | Owner and provider, based on the instruction and the route |
| Escalation | Call order for fire, alarm, hazard and access problems | Owner or GC |
| Change control | Who can add or remove areas, change hours or end coverage | Owner or GC |
Patrol route and checkpoints
A line like “patrol the building” cannot be checked later. Name each checkpoint in order on a marked floor plan: stairwells, corridors, mechanical and electrical rooms, storage rooms, roof access, loading docks, and areas where trades are working. Include unoccupied spaces that still hold combustible material, such as vacant units, storage rooms and construction floors, because they are easy to overlook when no one works there. If a door on the route is locked, the scope should say who provides the key or access card, or that the area is excluded and why.
On construction sites, NFPA 241 (opens in a new tab) covers safeguarding construction, alteration and demolition operations, and NFPA 51B (opens in a new tab) covers fire prevention during welding, cutting and other hot work. If hot work is underway, the scope should state whether the fire watch officer also covers hot work areas or whether the trade provides its own hot work fire watch. Leave no doubt about who owns it.
Staffing, equipment and site access
Staffing depends on how far the route runs, how many buildings or floors it covers and the round frequency the fire official sets. Our guide on how many fire watch officers you need walks through that math. The scope should also list:
- Phones or radios, and a backup way to call 911
- Locations of portable fire extinguishers, if the site expects the officer to use them, and confirmation that they are in service
- Flashlights, any required PPE for active construction areas, and site orientation
- Keys, access cards, gate codes and after-hours entry instructions
- Where the officer parks, checks in and keeps the log
Logs, escalation order and shift handover
The log is the record that the watch actually happened. Fairfax County’s fire watch personnel guidance (opens in a new tab) lists the date, tour start and end times, areas checked, findings or actions, and the name of the person on watch as minimum log entries. The same page says fire watch personnel keep diligent watch for fires, obstructions to means of egress and other hazards. Use that as a baseline and add anything your own fire official asks for. See fire watch log requirements for more.
Write escalation as an ordered sequence, not a contact list. The officer calls 911 first for any fire or smoke. The next calls go to the site contact, the property manager or GC superintendent, and the fire protection contractor. Give a backup for each contact. Also state where logs go at shift change and at the end of the assignment.
Ending coverage on restoration, not a calendar date
Tie the end of coverage to impairment status, not a date. Repairs slip, and a watch that ends on a fixed date can leave the building unprotected. The scope should say coverage ends only when the system is restored and tested, the fire official or the owner’s designee releases the watch, and that release is recorded in the log. Name the person who can authorize the stop.
Scope mistakes to avoid:
- A fixed end date instead of an end condition
- Vague routes with no checkpoints or floor plan
- Unoccupied areas with real fire load left out
- Round frequency written by the vendor instead of taken from the fire official
- No owner for hot work coverage on active construction sites
For planned outages, see planned fire system repairs. For unexpected ones, see sprinkler system outages.
How NESF handles fire watch assignments
North Eastern Security Force provides fire watch with unarmed, uniformed officers under Virginia DCJS license #11-6371. We staff fire watch to the fire official’s instructions, work from written post orders built on your scope, and turn in written shift reports, with logs handed over at each shift change. Our coverage includes suppression system impairments, fire pump impairments, planned system maintenance and hot work fire watch, along with construction site security and access control officers. NESF is fully insured, and a certificate of insurance is available on request.
Send your scope or impairment details to NESF
Send us the fire official’s instruction, the affected areas and your site contacts, and we will build post orders around them. Request a fire watch proposal, call 703-869-6213 (answered 24/7) or email info@nesf.us.
Fire watch scope of work questions
Can the security company decide how often fire watch rounds happen?
No. In Virginia, the local fire official sets fire watch requirements, including round frequency. The security provider should staff and schedule to that instruction. If the instruction is unclear, ask the fire official to clarify before coverage begins.
Who should sign off before the fire watch ends?
The scope should name the person who can authorize the stop, normally the owner’s representative. That person should act only after the fire protection contractor confirms the system is restored and tested and the fire official releases the watch where required. Record the release in the fire watch log.
Does a fire watch officer also cover hot work on a construction site?
Only if the scope says so. NFPA 51B addresses hot work fire watch separately. Your scope should state whether the impairment fire watch officer covers hot work areas or whether the trade doing the work provides its own fire watch.
What should I send a provider to get an accurate fire watch proposal?
Send the fire official’s instruction, the impaired system and affected areas, a floor plan or site map, the shift hours needed, site access details and your escalation contacts. With these, the provider can work out staffing and write post orders.
From a phone call to an officer on post.
- Tell us the site Address, hours, access points, and what the officer is watching.
- Post orders and rate Duties, patrol pattern and rate confirmed in writing up front.
- Officers on post Officers work the orders, log the shift, escalate to your contact.
Coverage is scheduled around the site, the hours and officer availability.
Coverage request
Request security coverage
Tell us the site, the hours you need covered and when it starts. If the coverage is needed today, calling 703-869-6213 is faster than this form.