Fire Pump Impairment Fire Watch

When a fire pump or related protection component is impaired, the responsible parties may be directed to establish temporary fire watch under site-specific requirements.

Virginia DCJS #11-637124/7 Coverage RequestsStatewide Virginia ServiceRated 4.5 on Google (16 reviews) (opens in a new tab)

Get a quote

Tell us the site, dates and coverage you need. The line is answered 24/7.

  • Requests any hour Nights, weekends and holidays included.
  • Named escalation Escalation contacts fixed before an officer arrives.
  • DCJS #11-6371 Licensed Virginia security business.
  • Unarmed officers Uniformed officers, no firearms on any assignment.

When a fire pump is out of service, the sprinkler or standpipe system it supports may not have the pressure it was designed for. North Eastern Security Force provides unarmed, DCJS-licensed fire watch officers who patrol the affected areas, watch for fire, report blocked exits or fire department access, and log rounds according to the fire official’s instructions.

Why a fire pump impairment can lead to a fire watch

A fire pump boosts water pressure for sprinkler and standpipe systems when the incoming supply alone is not enough. If the pump, its controller, its power supply or a related valve is out of service, part or all of the building may lose that protection, during a planned repair or without warning.

The Virginia Statewide Fire Prevention Code (SFPC) covers this in Section 901.7, Systems Out of Service. When a required fire protection system is out of service, the fire department and the fire code official must be notified immediately. Where the fire code official requires it, the building must either be evacuated or an approved fire watch provided for all occupants left unprotected. The fire official decides whether a watch is needed, how it is run and when it can end. Get those instructions in writing and give a copy to your fire watch provider.

An exception covers facilities with an approved impairment management program, which for water-based systems follows NFPA 25.

The impairment coordinator and who gets notified

The SFPC requires the building owner to assign an impairment coordinator. If no one is assigned, the owner is the coordinator. The coordinator authorizes planned impairments, handles notifications and makes sure the system is tagged.

When Who the code lists
System goes out of service Fire department and fire code official, immediately
Before a planned impairment is authorized (and after an emergency impairment) Fire department; insurance carrier; alarm company; building owner or manager; other authorities having jurisdiction; supervisors in the affected areas
Protection restored Supervisors and the fire department; building owner or manager; insurance carrier; alarm company; other involved parties

An impairment tag must show that the system, or part of it, is out of service. The code lists places such as each fire department connection, system control valve, fire alarm control unit, fire alarm annunciator and fire command center, and the fire official can specify where the tag goes. If the post orders call for it, the officer can note on each round whether the tags are still posted.

What the officer watches and records

Under the SFPC, fire watch personnel patrol the protected premises and keep watch for fires. The post orders you approve, built around the fire official’s instructions, set out the route and what to report. A typical post covers:

  • Patrolling every area the impaired system serves, such as stairwells, corridors, storage rooms, mechanical spaces and parking levels.
  • Watching for smoke, heat, odors, open flames and other ignition sources.
  • Noting and reporting blocked or chained exits, stair doors and egress paths.
  • Noting and reporting vehicles, dumpsters or materials blocking fire department connections, hydrants, fire lanes or the pump room door.
  • Calling 911 if a fire is found, then the contacts named in the post orders.
  • Logging each round with the time, areas checked, conditions found and anyone notified.

For what a complete log should contain, see our fire watch log requirements guide.

What the officer does not do in the pump room

Officers are not pump technicians. They do not start, stop, test, reset or diagnose the fire pump, its controller or its valves. If the post orders call for it, the officer can look into the pump room and report visible conditions, such as water on the floor or an alarm showing on the controller. Inspection, testing and repair belong to your fire protection contractor, working under NFPA 25 (Standard for the Inspection, Testing, and Maintenance of Water-Based Fire Protection Systems).

Checklist: what to have ready

  1. The fire official’s instructions for the watch, in writing if possible.
  2. The impairment coordinator’s name and phone number, plus an after-hours backup.
  3. Which system is impaired and which floors, buildings or areas it serves.
  4. Floor plans or a marked site map showing the patrol route, pump room, risers, fire department connections and exits.
  5. Keys, access cards or gate codes for every area the officer must check.
  6. Contacts for the fire protection contractor, alarm company and property management.
  7. How you will tell the officer that protection is restored.
  8. Site rules, such as hot work permits, contractor sign-in or restricted areas.

How NESF staffs a fire pump impairment watch

North Eastern Security Force is a Virginia private security company, DCJS license #11-6371, in business since December 2009. Our officers are unarmed and uniformed. For a fire pump impairment we:

  • Staff the fire watch to the fire official’s instructions.
  • Write site-specific post orders listing the patrol route, the checks and the contacts.
  • Have officers log every round and complete a written report each shift.
  • Pass logs on at each shift change so the next officer knows what was found.
  • Provide a certificate of insurance on request.

When coverage can start depends on your location and on officer availability. If the outage is already under way, say so when you call. Our emergency fire watch page explains what to have ready.

Before protection is restored, the SFPC has the impairment coordinator confirm that the needed inspections and tests show the system works, that the listed parties have been told, and that the impairment tag is removed. Do not end the watch just because a scheduled time has passed. End it when protection is restored and the fire official’s release conditions are met.

A fire pump problem can come with other impairments. See sprinkler outage fire watch, fire alarm outage watch, fire suppression system impairment, planned fire system maintenance and construction fire watch, or start at our fire watch services overview. For background, read the Virginia fire watch guide.

To request coverage, call 703-869-6213 (24/7) or use our contact form. Include the site address, the impaired system, the hours you need covered and an on-site contact.

Fire pump impairment questions

Does a fire pump being out of service always require a fire watch?

Not always. Under Section 901.7 of the Virginia Statewide Fire Prevention Code, the fire department and fire code official must be notified, and where the fire code official requires it, the building must be evacuated or an approved fire watch provided. Follow the fire official’s instructions and get them in writing.

Will your officer fix or reset the fire pump?

No. Officers patrol, watch for fire, report hazards and blocked exits or fire department access, and log their rounds. They can report visible conditions at the pump room if the post orders call for it. Testing and repair are done by your fire protection contractor.

Who else should we notify about a fire pump impairment?

The SFPC lists the fire department, the fire code official, your insurance carrier, your alarm company, the building owner or manager, other authorities having jurisdiction, and supervisors in the affected areas. Your impairment coordinator handles these notifications and tells the listed parties when protection is restored.

What records do we get from the watch?

Officers log each round with the time, areas checked, conditions found and anyone notified, and complete a written report each shift. Those records can be shared with the fire official or your insurer.

How coverage gets set up.

  1. Tell us the site Address, hours, access points, and what the officer is watching.
  2. Post orders and rate Duties, patrol pattern and rate confirmed in writing up front.
  3. Officers on post Officers work the orders, log the shift, escalate to your contact.

Coverage is scheduled around the site, the hours and officer availability.

Coverage request

Request coverage for this site

Tell us the site, the hours you need covered and when it starts. If the coverage is needed today, calling 703-869-6213 is faster than this form.

Required field

Call 703-869-6213 instead
  • Virginia DCJS #11-6371 · unarmed uniformed officers
  • Written site-specific post orders and documented reporting on every shift
  • Requests taken at any hour, including nights, weekends and holidays
  • Used only to answer this request — privacy policy

If there is an active emergency or an immediate threat to life, contact the public emergency services first.